| Application | Operating Parameters | FASTLOCK™ EPDM Application |
| Fluids | ||
| Hot and Cold Potable Water | 32° F – 250° F; Max. 200 PSI | YES |
| Potable Water System Flushing | Compliant with Major Plumbing Codes | YES |
| Chilled Water with Corrosion Inhibitors | 0° F – 250° F; Max. 200 PSI Ethylene Glycol (50% Max. Conecentration) Propylene Glycol (50% Max. Concentration) |
YES |
| Hydronic Heating | 0° F – 250° F; Max. 200 PSI Ethylene Glycol (50% Max. Conecentration) Propylene Glycol (50% Max. Concentration) |
YES |
| Low Pressure Steam (WARNING: Application must be within operating parameters of FastLock fittings: 0° F – 250° F; Max. 200 PSI) | 0° F – 250° F; Max. 200 PSI | YES |
| Rainwater/Greywater | 32° F – 250° F; Max. 200 PSI | YES |
| Heating Fuel Oil | -40° F – 180° F Ambient; Max. 125 PSI | NO |
| Diesel Fuel Oil | Compliant with NFPA 30 and 30A | NO |
| Process Plumbing | ||
| Propylene Glycol (100% Max. Concentration) | 0° F – 250° F; Max. 200 PSI | YES |
| Ethylene Glycol (100% Max. Concentration) | 0° F – 250° F; Max. 200 PSI | YES |
| Butylene Glycol (100% Max. Concentration) | 0° F – 250° F; Max. 200 PSI | YES |
| Gases | ||
| Compressed Air with less than 25mg/m3 oil content | 0° F – 160° F Ambient; Max. 200 PSI | YES |
| Compressed Air with greater than 25mg/m3 oil content | 0° F – 160° F Ambient; Max. 200 PSI | NO |
| Carbon Dioxide CO2 Dry | 0° F – 250° F Ambient; Max. 140 PSI | YES |
| Nitrogen N2 | 0° F – 250° F Ambient; Max. 140 PSI | YES |
| Argon | 0° F – 250° F Ambient; Max. 140 PSI | YES |
| Corgon | 0° F – 250° F Ambient; Max. 140 PSI | YES |
| Vacuum | Max. 29.2 Inches of Mercury | YES |
| Natural Gas, Liquid Propane Gas, Mixed Fuel Gases, Manufactured Fuel Gases, Liquid Butane Gas | -40° F – 180° F Ambient; Max. 125 PSI | NO |
| Oxygen O2 (non-medical) | 0° F – 160° F Ambient; Max. 160 PSI | YES |